ÌÇÐÄÊÓÆµ


Improving detector sensitivity to neutrinos and dark matter: Latest experimental setup yields 50% higher ionization

Improving detector sensitivity to neutrinos and dark matter
Simplified diagram of the experimental setup. A HPGe detector was placed within the collimated neutron beam, and a NaI(Tl) detector was placed to the side outside the neutron beam. Credit: ÌÇÐÄÊÓÆµical Review D (2024). DOI: 10.1103/ÌÇÐÄÊÓÆµRevD.110.083043

Fine tuning an experimental setup improved a detector's sensitivity to neutrinos and perhaps eventually dark matter—two difficult-to-measure forms of matter which hold great importance for understanding particle physics and experimental cosmology. The University-of-Michigan-led study is in ÌÇÐÄÊÓÆµical Review D.

The trouble with detecting neutrinos and lies in their with other forms of matter.

±·±ð³Ü³Ù°ù¾±²Ô´Ç²õ—t¾±²Ô²â, produced in in the stars and by —only rarely interact with other matter through weak nuclear forces. Typically, neutrinos pass straight through visible matter, earning the nickname "ghost particles." These neutrally charged particles do not interact with electromagnetic forces, and they only weakly interact with gravity as their mass is around ten million times less than an electron.

Neutrinos can be detected through nuclear recoil. When trillions of neutrinos are directed at atoms, a rare collision between a neutrino and an atom can occur. This causes the nucleus to recoil and pushes electrons of nearby atoms out of orbit. Applying a voltage across the detector and recording ionization energy reveals neutrino collisions.

Similarly elusive, dark matter exerts gravitational force upon visible matter but does not absorb, reflect or emit light. Researchers are actively working to create and detect dark matter, thought to be the "glue" holding galaxies together, to better understand the formation of the universe.

Although dark matter has not yet been detected on earth, hypothetical particles called Weakly Interacting Massive Particles (WIMPs) are expected to cause nuclear recoil similar to .

Once only able to be detected in massive underground facilities, commercially available high purity germanium detectors, or HPGe detectors, just a few inches long are now able to detect weak nuclear recoils. These compact detectors leverage the heavy metal's large nucleus to increase the probability of collisions while cooling the detector to 77 Kelvin (about -196 ℃) to minimize signal noise from atomic vibrations.

Improving detector sensitivity to neutrinos and dark matter
Experimental set up at The Ohio State University Nuclear Reactor Laboratory. The high purity germanium detector (HPGe) is within the path of a neutron beam while the sodium iodide (NaI) scintillation detector is placed to the side of the beam. Credit: Applied Nuclear Science Group (Prof. Jovanovic).

To accurately detect these tiny disturbances, detectors must first measure and understand nuclear recoils under a neutron beam to ensure proper calibration.

"Radiation is the means by which we observe the universe, be it in the Large Hadron Collider, dark matter experiments or nuclear experiments. Understanding how that radiation interacts with matter greatly impacts our ability to interpret measured results," said Igor Jovanovic, a U-M professor of nuclear engineering and radiological sciences and senior author of the study.

The research team performed an experiment measuring the response of germanium nuclei to 254 electron volt (eV) nuclear recoils, or about one fourth of a keV, as nuclear recoils to lower energy neutron beams are poorly understood. Two previous experiments measuring nuclear recoil at the same energy had conflicting ionization yields.

The used a two cubic centimeter HPGe detector and an external sodium iodide (NaI) scintillation detector to measure ionizing radiation from nuclear recoils. To reconcile previous experimental differences, the researchers saved the raw output from both the HPGe and NaI detector using improved digital electronic recording devices.

Using the raw output improved shaping analysis, removing any signal processing biases, and allowed the same data to be analyzed using multiple algorithms to find the optimal method.

Results yielded a 50% higher ionization yield compared to a previously established theory, dramatically increasing the sensitivity of high purity germanium detectors to dark matter or neutrino detection.

"Our results could greatly improve the sensitivity of commercially available technologies for neutrino detection and impact the results of several ongoing neutrino experiments," said Alexander Kavner, a U-M doctoral graduate in the Applied ÌÇÐÄÊÓÆµics Program and lead author of the study.

Experimentation was conducted at The Ohio State University Nuclear Reactor Laboratory.

More information: A. R. L. Kavner et al, Measurement of ionization produced by 254 eVnr nuclear recoils in germanium, ÌÇÐÄÊÓÆµical Review D (2024). . On arXiv:

Journal information: ÌÇÐÄÊÓÆµical Review D , arXiv

Citation: Improving detector sensitivity to neutrinos and dark matter: Latest experimental setup yields 50% higher ionization (2024, November 4) retrieved 27 June 2025 from /news/2024-11-detector-sensitivity-neutrinos-dark-latest.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.

Explore further

First neutrinos detected at Fermilab short-baseline detector

44 shares

Feedback to editors